Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMC Oral Health ; 21(1): 81, 2021 02 22.
Artigo em Inglês | MEDLINE | ID: mdl-33618701

RESUMO

BACKGROUND: Irrigation of the pulp space is a mandatory step to get rid of all its organic and inorganic content. Activation of the irrigants play a key role in the era of minimally invasive endodontics. The aim of this study was to assess the effectiveness of different irrigants activation methods in removing the smear layer at 1, 3, 5 and 8 mm from the apex from conservatively shaped canals. METHODS: Eighty-five human mandibular premolars were selected. Specimens were shaped to TruShape 25/.06 and divided into 5 groups (1 control and 4 test groups) according to the final activation technique (EndoActivator, EA), Ultrasonic (EndoUltra, PUI) and Laser (PIPS and SWEEPS). EDTA (Ethylenediaminetetraacetic acid) followed by NaOCl (Sodium Hypochlorite) and again EDTA were activated for each test group. Specimens were then split longitudinally and observed by Field Emission Scanning Electron Microscopy (FESEM). Blinded evaluation of the presence of smear layer was performed at 1000X magnification, according to a 5-score index system. Comparison between groups were analysed statistically using the Kruskal-Wallis non-parametric analysis of variance. Bonferroni multiple comparison tests were used. RESULTS: At 1 mm only PIPS and SWEEPS performed better than the control group. At 3, 5 and 8 mm from the apex, every activation technique showed statistically significant reduction of smear layer when compared to the control group. PIPS and SWEEPS obtained better cleanliness result compared to EA, while only PIPS was superior to PUI in terms of cleanliness. CONCLUSIONS: PIPS and SWEEPS showed the best results in conservative canal preparations. Nowadays, contemporary rotary instruments allow fast and minimally invasive shaping of the endodontic space. In this scenario irrigants' activation may be regarded as a mandatory step to a favourable clinical outcome.


Assuntos
Camada de Esfregaço , Cavidade Pulpar , Ácido Edético , Humanos , Lasers , Microscopia Eletrônica de Varredura , Irrigantes do Canal Radicular/uso terapêutico , Preparo de Canal Radicular , Hipoclorito de Sódio/uso terapêutico , Irrigação Terapêutica , Ultrassom
2.
Clin Oral Investig ; 22(2): 993-999, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28721527

RESUMO

OBJECTIVES: This study was to compare the efficacy of EndoActivator, EndoVac, PUI, and LAI methods in removing the smear layer from root canals. MATERIALS AND METHODS: Eighty single-rooted mandibular premolars were decoronated to a standardized length of 15 mm. Specimens were shaped to ProTaper F4 (Dentsply Maillefer) and irrigated with 5.25% NaOCl at 37 °C. Teeth were divided into six groups (two control groups [n = 10] and four test groups [n = 15]) according to the final irrigation activation/delivering technique (sonic irrigation [EndoActivator], passive ultrasonic irrigation [PUI], negative apical pressure [EndoVac], and laser activated irrigation [LAI]). Root canals were then split longitudinally and observed with field emission scanning electron microscopy to evaluate the presence of smear layer at 1, 3, 5, and 8 mm from the apex. Scores were analyzed by Kruskal-Wallis and Mann-Whitney U tests. RESULTS: The EndoActivator was significantly more efficient than PUI, LAI, and control groups in removing the smear layer at 3, 5, and 8 mm from the apex. The EndoVac System removed statistically significantly more smear layer than all groups at 1 mm from the apex. At 5 mm from the apex, EndoActivator and EndoVac removed more smear layer than LAI and control groups. At 5 and 8 mm from the apex, PUI and EndoVac did not differ statistically, but both performed statistically better than the control groups. CONCLUSION: In our study, none of the activation/delivery systems completely removed the smear layer from the root canal walls; nevertheless, EV and EA showed, respectively, statistically significant better results at 1, 3, 5, and 8 mm and 3, 5, and 8 mm from the apex.


Assuntos
Cavidade Pulpar/ultraestrutura , Microscopia Eletrônica de Varredura/métodos , Camada de Esfregaço , Irrigação Terapêutica/métodos , Dente Pré-Molar , Humanos , Técnicas In Vitro , Terapia a Laser , Irrigação Terapêutica/instrumentação , Terapia por Ultrassom , Vácuo
3.
J Endod ; 40(12): 2061-5, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25443281

RESUMO

INTRODUCTION: This ex vivo study evaluated the accuracy of the Root ZX electronic apex locator (EAL) (J Morita Corp, Kyoto, Japan) in determining the working length during retreatment of canals sealed with 2 different carrier-based obturating materials (ProTaper Obturator [Dentsply Maillefer, Ballaigues, Switzerland] and GuttaCore [Dentsply Maillefer]) and also evaluated whether they influenced its accuracy differently. METHODS: Fifty extracted single-rooted human teeth with sound apices were selected for the study. We measured canals with the direct visual technique using a #10 K-file and shaped them with ProTaper Universal instruments (Dentsply Maillefer) up to this predetermined length. After instrumentation, we determined the canal length again using the visual technique (direct length [DL]). This value was considered the "reference point." Specimens were then placed in a tooth holder (Pro-Train; Simit Dental, Mantova, Italy), and the canal length was electronically measured (electronic length 1 [EL1]). Specimens were then obturated with ProTaper Obturators (group 1, n = 25) and GuttaCore (group 2, n = 25). Seven days later, a new electronic length was determined (electronic length 2 [EL2]) during retreatment procedures in the presence of the obturating material. EL1 and EL2 values were compared with DL using the Bland and Altman method. The different influences of the tested materials on the accuracy of the EAL were calculated with repeated measures analysis of variance. RESULTS: Both EL1 and EL2 values provided a statistically significant overestimation of the actual canal length (DL [P < .05]), with the EL2 values higher from DL. The 2 different materials did not influence the accuracy of the EAL differently (P = .486). CONCLUSIONS: The measurements obtained with the EAL tested during orthograde retreatments can lead clinicians to overinstrumentation and consequent overfilling of the endodontic space.


Assuntos
Cavidade Pulpar/anatomia & histologia , Equipamentos e Provisões Elétricas/estatística & dados numéricos , Odontometria/instrumentação , Materiais Restauradores do Canal Radicular/uso terapêutico , Obturação do Canal Radicular/métodos , Preparo de Canal Radicular/instrumentação , Ápice Dentário/anatomia & histologia , Dente não Vital/patologia , Calibragem , Reagentes de Ligações Cruzadas/uso terapêutico , Guta-Percha/uso terapêutico , Humanos , Teste de Materiais , Odontometria/estatística & dados numéricos , Plásticos/uso terapêutico , Retratamento , Preparo de Canal Radicular/estatística & dados numéricos
4.
J Endod ; 39(11): 1456-60, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24139274

RESUMO

INTRODUCTION: The purpose of this study was to evaluate the effectiveness of different irrigating methods in removing the smear layer at 1, 3, 5, and 8 mm from the apex of endodontic canals. METHODS: Sixty-five extracted single-rooted human mandibular premolars were decoronated to a standardized length of 16 mm. Specimens were shaped to ProTaper F4 (Dentsply Maillefer, Ballaigues, Switzerland) and irrigated with 5.25% NaOCl at 37°C. Teeth were divided into 5 groups (2 control groups [n = 10] and 3 test groups [n = 15]) according to the final irrigant activation/delivering technique (ie, sonic irrigation, passive ultrasonic irrigation [PUI], or apical negative pressure). Root canals were then split longitudinally and observed by field emission scanning electron microscopy. The presence of debris and a smear layer at 1, 3, 5, and 8 mm from the apex was evaluated. Scores were analyzed by Kruskal-Wallis and Mann-Whitney U tests. RESULTS: The EndoActivator System (Dentsply Tulsa Dental Specialties, Tulsa, OK) was significantly more efficient than PUI and the control groups in removing the smear layer at 3, 5, and 8 mm from the apex. The EndoVac System (Discus Dental, Culver City, CA) removed statistically significantly more smear layer than all groups at 1, 3, 5, and 8 mm from the apex. At 5 and 8 mm from the apex, PUI and the EndoVac did not differ statistically significantly, but both performed statistically better than the control groups. CONCLUSIONS: In our study, none of the activation/delivery systems completely removed the smear layer from the endodontic dentine walls; nevertheless, the EndoActivator and EndoVac showed the best results at 3, 5, and 8 mm (EndoActivator) and 1, 3, 5, and 8 mm (EndoVac) from the apex.


Assuntos
Cavidade Pulpar/ultraestrutura , Irrigantes do Canal Radicular/administração & dosagem , Camada de Esfregaço/terapia , Irrigação Terapêutica/instrumentação , Adolescente , Adulto , Dentina/ultraestrutura , Ácido Edético/administração & dosagem , Humanos , Teste de Materiais , Microscopia Eletrônica de Varredura , Preparo de Canal Radicular/instrumentação , Camada de Esfregaço/patologia , Hipoclorito de Sódio/administração & dosagem , Sonicação/instrumentação , Temperatura , Ápice Dentário/ultraestrutura , Ultrassom/instrumentação , Vácuo , Adulto Jovem
5.
J Endod ; 37(5): 684-7, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21496671

RESUMO

INTRODUCTION: The aim of this study was to determine in anterior teeth, bicuspids, and molars (1) the accuracy of 3 different electronic apex locators (EALs) in detecting the apical foramen and (2) the accuracy of digital radiography in determining the working length (WL), compared with visible control under a microscope. METHODS: By using radiovideography (RVG), we measured the lengths of 120 root canals with 3 different EALs (Endex, ProPex II, and Root ZX) and compared them with the actual lengths. The accuracy of EALs and RVG was related to each dental category. An endodontic training kit (Pro-Train) was used during experimental procedures. RESULTS: Statistical analysis showed that the 3 EALs and RVG were less accurate in anterior teeth and molars than in bicuspids. The paired-sample t test showed no statistically significant difference between mesiodistal plane and buccolingual plane digital radiography in all groups. CONCLUSIONS: The 3 EALs tested were more accurate in detecting the apical foramen in bicuspids than in both molars and anterior teeth. Radiographic measurements were not reliable for determining WL in all dental groups in both radiographic planes.


Assuntos
Cavidade Pulpar/anatomia & histologia , Odontometria/instrumentação , Ápice Dentário/anatomia & histologia , Adulto , Dente Pré-Molar/anatomia & histologia , Cinerradiografia , Dente Canino/anatomia & histologia , Cavidade Pulpar/diagnóstico por imagem , Equipamentos e Provisões Elétricas/estatística & dados numéricos , Desenho de Equipamento , Humanos , Incisivo/anatomia & histologia , Microscopia/estatística & dados numéricos , Pessoa de Meia-Idade , Dente Molar/anatomia & histologia , Odontometria/estatística & dados numéricos , Radiografia Dentária Digital/estatística & dados numéricos , Preparo de Canal Radicular/instrumentação , Ápice Dentário/diagnóstico por imagem , Raiz Dentária/anatomia & histologia
6.
Dent Mater J ; 30(2): 216-21, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21383518

RESUMO

This study evaluated the shear bond strength, failure modes, and confocal microscopy of two different amalgam alloy restorations lined with five adhesive systems. Two regular-set high-copper dental amalgam alloys, Amalcap Plus and Valiant Ph.D, and five commercially available adhesive systems were selected. One hundred and twenty freshly-extracted human third molars were used for the study. The results were statistically evaluated using two-factor analysis of variance (ANOVA). The shear bond strength (SBS) of amalgam to dentin was significantly affected by both the adhesive (p<0.0001) and amalgam alloy (p<0.0002). Regarding mode of failure (MF), among samples restored with Valiant Ph.D, 31 of 50 exhibited adhesive failure, and 19 displayed mixed failure. Laser optical microscopy (OM) of the bonded interface revealed the presence of a good hybrid layer was evident in all experimental groups. Higher bond strengths were measured for four of the five adhesives when used in combination with the spherical alloy.


Assuntos
Ligas Dentárias/química , Amálgama Dentário/química , Restauração Dentária Permanente , Cimentos de Resina/química , Autocura de Resinas Dentárias , Condicionamento Ácido do Dente , Adesividade , Corantes , Forramento da Cavidade Dentária , Análise do Estresse Dentário , Dentina/ultraestrutura , Adesivos Dentinários/química , Humanos , Metacrilatos/química , Microscopia Confocal , Ácidos Polimetacrílicos/química , Resistência ao Cisalhamento , Estresse Mecânico
7.
J Endod ; 36(12): 2003-7, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21092822

RESUMO

INTRODUCTION: This study compared (1) the accuracy of three different electronic apex locators (EALs) in detecting the apical foramen ex vivo under clinical conditions; (2) the accuracy of digital radiography and EALs in determining the working length (WL) with visible control under a microscope; and (3) the precision of #10, #15, and #20 K-files in electronic measurements. METHODS: The length of 101 extracted human teeth was measured with three different EALs (Endex [Osada Electric Co, Tokyo, Japan], ProPex II [Dentsply-Maillefer, Ballaigues, Switzerland], and Root ZX [J. Morita Co, Tustin, CA]), with radio videography (RVG) and compared with the actual length. An endodontic training kit (Pro-Train; Simit Dental, Mantova, Italy) was used during the experimental procedures. RESULTS: Statistical analysis showed that Endex and ProPex II were more accurate than Root ZX in determining the WL. The paired sample t test showed no statistically significant difference between the accuracy of the two radiographic planes examined. The t test showed no significant difference between the three different K-file sizes measurements. CONCLUSIONS: Endex and ProPex II were more accurate than Root ZX in determining the actual WL. Instrument sizes of hand files did not affect the accuracy of EALs. EALs showed to be more accurate in determining the WL than RVG.


Assuntos
Equipamentos Odontológicos , Cavidade Pulpar/anatomia & histologia , Odontometria/instrumentação , Radiografia Dentária Digital , Ápice Dentário/anatomia & histologia , Adulto , Cavidade Pulpar/diagnóstico por imagem , Humanos , Pessoa de Meia-Idade , Odontometria/métodos , Reprodutibilidade dos Testes , Preparo de Canal Radicular/instrumentação , Ápice Dentário/diagnóstico por imagem
8.
J Endod ; 35(6): 900-3, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19482195

RESUMO

INTRODUCTION: This study compared the efficacy of BioPure MTAD (Dentsply Tulsa, Tulsa, OK), 17% EDTA, and 42% citric acid in endodontic smear layer removal and degree of erosion in the apical third of endodontic canals. METHODS: Ninety-six extracted single-rooted human teeth were randomized into four groups (n = 24) and instrumented using System GT nickel-titanium rotary instruments (Dentsply Tulsa, Tulsa, OK). Each canal was irrigated with one of the following solutions: BioPure MTAD, 17% EDTA, 42% citric acid, or 5.25% NaOCl (control). Next, all specimens were irrigated with 5.25% NaOCl. RESULTS: Evaluation by scanning electron microscopy showed no significant differences among test irrigants in removing the smear layer. However, the efficacy of BioPure MTAD and 17% EDTA in removing the smear layer was significantly greater than 5.25% NaOCl (control). The erosive effects of irrigating solutions could not be evaluated. CONCLUSIONS: In conclusion, the protocols used in this study were not sufficient to completely remove the smear layer in the apical third of prepared root canals.


Assuntos
Irrigantes do Canal Radicular/farmacologia , Preparo de Canal Radicular/métodos , Camada de Esfregaço , Adulto , Ácido Cítrico/efeitos adversos , Ácido Cítrico/farmacologia , Doxiciclina/efeitos adversos , Doxiciclina/farmacologia , Ácido Edético/efeitos adversos , Ácido Edético/farmacologia , Humanos , Microscopia Eletrônica de Varredura , Pessoa de Meia-Idade , Polissorbatos/efeitos adversos , Polissorbatos/farmacologia , Irrigantes do Canal Radicular/efeitos adversos , Hipoclorito de Sódio/farmacologia , Erosão Dentária/induzido quimicamente , Falha de Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...